Article ID: 000074622 Content Type: Troubleshooting Last Reviewed: 05/31/2017

Why is an unexpected functional failure observed on Arria 10 devices when performing fault injection with the Fault Injection Debugger IP?

Environment

  • Intel® Quartus® Prime Pro Edition
  • Advanced SEU Detection Intel® FPGA IP
  • Fault Injection Intel® FPGA IP
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    Due to an issue in Quartus® Prime software versions earlier than 17.0, the Fault Injection Debugger IP may cause CRAM corruption during fault injection in Arria® 10 devices, which may lead to one of the following failures :

    - Fault Injection IP not found.

    - Lost SignalTap instance.

    - Failure to read the Error Message Register (EMR) or read invalid EMR content.

    - Internal Scrubbing cannot recover the functional failure in user logic.

     

    Resolution

    This issue is resolved in Quartus® Prime software version 17.0.

    Related Products

    This article applies to 1 products

    Intel® Arria® 10 FPGAs and SoC FPGAs