Article ID: 000082051 Content Type: Troubleshooting Last Reviewed: 08/27/2013

Why does CvP not work correctly when using the Avalon-MM PCIe Hard IP?

Environment

  • Quartus® II Subscription Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description Due to a known issue in Quartus® II software releases v12.0SP2 and earlier, Configuration via Protocol (CvP) will not work correctly if Avalon® MM mode is being used.
    Resolution

    To work around this issue in software version v12.0SP2, modify the auto-generated Qsys top level RTL file to ensure that the following parameters are set:

    .bypass_clk_switch_hwtcl                      ("false"),
    .cseb_cpl_status_during_cvp_hwtcl        ("completer_abort"),
    .core_clk_sel_hwtcl                              ("core_clk_250"),
    .rx_ei_l0s_hwtcl                                   (0),
    .enable_l0s_aspm_hwtcl                       ("false"),

    This issue is fixed in version 12.1sp1 of the Quartus II software.

    Related Products

    This article applies to 3 products

    Stratix® V GX FPGA
    Stratix® V GS FPGA
    Stratix® V GT FPGA